Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • 1210 °C target temperature
  • low vacuum at 5-10mbar, no process gas
  • used PolyMim PolyMIM 17-4PH feedstock, unmodified granules (not debindered)
  • Heating cycle
    • T+0min: Start: 15°C, 5mbar, cooling water temp 15 °C 
    • T+10min: Heating finished, 1210°C, 10mbar, cooling water temp 19 °C 
    • T+23min: Switched heating off, 1210°C, 8mbar, cooling water temp 25 °C 
    • T+33min: switched vacuum pump off, pressure stays at 4mbar
    • ca T+53min: opening chamber, ca 250°C

...